SH 3503-2001 SH 3503–J537 Installation and Adjustment Record of Circuit Breakers 断路器安装调整记录 Project Name:工程名称: Unit Name: 单元名称: Pos (Panel) No. 位(盘)号 Model 断路器型号 铭牌Model of actuator 操动机构型号 安装检查Description 名 称 Voltage level Manufacturer kV 电压等级 制 造 厂 Manu. date Manu. number 出厂日期 出厂编号 Items to be inspected 检 查 内 容 Intact appearance of circuit breakers and actuators, complete accessories and product technical documents 断路器、操动机构外观完好,附件、产品技术文件齐全 Circuit breakers and actuators are tightly installed in accordance with relevant specifications. 断路器、操动机构安装符合规范要求,安装牢固 Electrical connections are correct, reliable, and desirably contacted. Cable duct openings are sealed. 电气接线正确、可靠、接触良好,电缆管口密封 Flexible and reliable operations. Correct on/off indication. Rotating parts applied with applicable lubrication grease. 操作灵活、可靠,分、合闸指示正确,转动部分涂以适宜的润滑脂 Insulation parts are intact with clean surface and full painting. Phases are marked correctly in color. Well grounded. 绝缘件完整无损,表面清洁,油漆完整,相色标志正确,接地良好 Results结论 Nameplate Installation Inspection Installation adjustment Inspection results 检 查 结 果 安装调整Item 项 目 Full travel distance of conductive rod 导电杆全行程(mm) Depth of moving contact into fixed contact 动触头插入固定触头深度(mm) Standby travel after switch on 合闸后的备用行程(mm) Phase to phase maximum simultaneous incoming difference 相间同时最大接入差(mm) Spring buffer travel distance 弹簧缓冲器行程(mm) Oil buffer travel distance 油缓冲器行程(mm) Angular adjustment of three phase regulation lever 三相拐臂角度调整 Phase A 相 Phase B 相 Phase C 相 Notes 备注 Responsible technician 技术负责人: Quality inspector 质量检查员: Shift (team) leader 班(组)长: 年(YY) 月(MM) 日(DD)