三菱电梯GPS-3故障代码详细说明 MON1=1 MON0=0:

7SEG1=1:INV温度检测; =2:E-STOP次 =3:CC-WDT三次 =4:SLCWDT三次 =5:电机过电流 =6:制动器电阻过载 =7:接触器 故障

=8:终端减速开关故障 =9:平层开关故障 =A:称量装置故障 =B:E1板故障

=C:UHS/DHS开关故障 =D:DZ检测回路故障 =E\F:无 MON0=1:

7SEG1=1:远程复位检测; =2:选层器错误16次 =3:串行故障 =4:电容器容量不足 =5:手动运行按钮故障 =6:速度图形跳转5次

=7:#LB接触器动作失败5次 =8:#5接触器动作失败5次 =9:#BK1接触器动作失败5次 =A:#BK2接触器动作失败5次 =B:LVLT5次 =C:E1板故障 =D:风扇故障

=E\F:风扇或E1板故障 MON0=2:

7SEG1=1:#5 ON故障; =2:E-STOP两次 =3:系统故障 =4:再复位请求

=5:PCB基极驱动故障 =6:DC-CT故障

=7:无

=8:浸水感应器故障 =9:反浸水动作结束

=A:#PWD开关指令持续三分钟 =B:扶手开关保持 =C:制动器拖动运行结束 =D:制动器再动作故障 =E:无

=F:选层器故障运行16次 MON0=3:

7SEG1=1:MELD过载; =2:异常低速 =3:异常高速 =4:反转定时 =5:反向运行

=6:反转定时器(CWT)

=7:反转定时器(CWT BS标准) =8:逆变器过电压 =9:逆变器欠电压 =A:CC-WDT四次 =B:SLC-WDT 4次 =C:逆变器过电流

=D:SLC E-STOP =E:编码器故障(自动) =F:编码器故障(手动) MON0=4:

7SEG1=1:两次E-STOP; =2:INV欠电压

=3:E-STOP F/F复位 =4:#LB线圈故障 =5:#5线圈故障 =6:#BK1线圈故障 =7:#BK2线圈故障 =8:上电 =9:无 =A:无

=B:逆变器充电失败 =C\D\E\F:无 MON0=5:

7SEG1=1:电气安全回路

=2:#29锁存 =3:断电

=4:INV欠电压 =5:12V电源故障 =6:控制屏打开 =7:手动过载运行

=8:驱动S/W E-STOP =9:管理S/W E-STOP =A:无

=B:异常制动器滑动距离 =C\D\E\F:无 MON0=6:

7SEG1=1:逆变器欠压; =2:PCB基极驱动故障 =3:INV保护回路动作 =4:#29锁存 =5:12V电源故障 =6:温度开关超75度 =7:温度开关超90度 =8